Hy-800 barrel nickel plating

2022-09-05 691

1、 Operating conditions

Nickel sulfate: 150-250g / L

Nickel chloride: 40-50g / L

Boric acid: 40-50g / L

HY-800:0.4ml/l

HY-801:10ml/l

Temperature: 50-60 ℃

Current density: 0.2-2asd


2、 Product characteristics

The coating has fast light output, good displacement ability, low stress and can withstand post plating machining.

When hy-800 is selected, the coating is clear, and when hy-800a is selected, the coating is white and bright.

It is also applicable to nickel flash plating after copper acid.